Permit: T06CM00988

Parcel: 120021370


Addresses:

4220 S 13TH AV

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
09/04/2008 BUILDING - FINAL Approved LETTER OF COMPLETION ONLY FOR REPAIRS AND REMODEL.
08/21/2008 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LABEL CIRCUITS MAIN PANEL
2) SECURE #4 TO BLDG
3) SEAL KNOCKOUT CIRCUITS 14 PANEL
4) EXTERIOR GFCI'S NOT UNDER ROOF MUST BE BUBBLE TYPE
5) MISSING EXTERIOR LIGHT FIXTURE REAR
6) GFCI PROTECT KITCHEN OUTLETS
7) PROVIDE WORKING SMOKIES HALLWAY AND BEDROOMS
8) MISSING COVER PLATE 220 STOVE
10) WHITE HOT LEAD 30 AMP MUST BE BLACK OR RED
11) NO POWER TO INTERIOR OUTLETS THROUGHOUT
12) NO PLANS OR PERMIT FOUND
07/14/2008 BUILDING - FINAL Partial Approval IVRS - Inspection :*
06/23/2008 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
FINALS NOT READY

1. MAKE UP ALL ELECTRIC FOR FINAL
2. INSTALL REGISTERS
3. REINSTALL AIR CONDITIONER
4. FINISH PLUMBING
5. GAS PRESSURE TEST REQUIRED @ FINAL

RECALL WHEN DONE