Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T06CM00976
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/24/2007 | PLUMBING - INTERMEDIATE | Approved | FLANGES OK | |
| 04/20/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* DOOR LOCKED UNABLE TO CALL -- PHONE DIED |
|
| 04/10/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* CLOSET FLANGE IS TO EXTEND 1/4" ABOVE FINISHED FLOOR |
|
| 11/06/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. GAS PRESSURE TEST OK NOTE: BOTH WATER HEATER GAS STUBS ARE STUBBED OUT ON THE SAME SIDE. 2. CORRECTIONS MADE OK OK TO COVER ALL AREAS 3. SECURE CLOSET FLANGES TO THE FLOOR AND RECALL 03035 FOR INSPECTION. |
|
| 11/01/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. PROVIDE AN APPROVED REVISED PLAN FOR THE GAS NOT INSTALLED PER PLAN. 2. SECURE CLOSET FLANGES TO THE FLOOR. 3. WATER TEST OK PEX OK TUBS OK |
|
| 10/20/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. ABS PIPING THRU BLOCK FOR VENT PIPING NOT UNDER TEST 2. ADD SUPPORT IN WALL FOR WATER PIPING AND VENT 3. FILL TUB HALFWAY OVER FLOW 4. DRYERS GAS PIPING NOT ON PLANS 5. LEAK OVERHEAD IN BATHROOM OF WEST UNIT 6. LIST MAY NOT BE COMPLETE |