Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM00974
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/12/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 05/11/2006 | FRAMING | Partial Approval | IVRS - Inspection :* 1) INSTALL HTT16 H/D AS REQUIRED 2) TIGHTEN ALL RED HEADS 3) ADD H2.5'S EACH SIDE OF GIRDER TRUSSES 4) GROUND METAL BOX GARAGE DOOR 5) 4 GANG BOXES NEED SUPPORT BOTH SIDES 6) MOVE ACCESS OPENING OR DUCT TO ACHIEVE REQUIRED ACCESS SPACE 7) CAULK BOX AT GARAGE DOOR |