Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T06CM00967
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/24/2006 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* CAP OK |
|
05/18/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* PIPE WRAPS OK WATER TEST WASTE & VENT IN VISION CENTER TO POINT OF EXISTING VENT CONNECTION OK. 1. NEED TO SEE CAP ON TEST WYE IN CEILING ON VENT. WATER PIPING OK VISION CENTER. |
|
05/17/2006 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* SPOKE TO PLUMBERS CON SITE ABOUT CORRECTIONS. |
|
05/15/2006 | PLUMBING - ROUGH, SOIL | Cancelled | CANCELLED PER CONTRACTOR JOSE #817-676-4992 | |
05/15/2006 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
05/12/2006 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* INSTALL PER APPROVED PLAN OR REVISE IT. PROVIDE CORRECT MATERIAL TYPES PER EXISTING. PROVIDE CORRECT DRAINAGE SYSTEMS WITH FITTINGS INSTALLED IN CORRECT DIRECTION FOR FLOW. HAVE YOUR PLUMBER ON SITE FOR RE-INSPECTION. |
|
05/11/2006 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - PLASTIC DWV THREADED FITTINGS CANNOT BE CONCEALED. - PROVIDE WATER TEST ON VENTS TO POINT OF CONNECTION TO EXISTING VENT. - PROVIDE PROPER SLOPE ON VENTS. - ELIMINATE TRAP AND RECEPTOR IN CEILING AT W.H. - SUPPORT DWV AT EVERY BRANCH AND AT 4' INTERVALS. - EXPOSE TIE IN PANT OF WASTE CONNECTIONS. - PROTECT PLASTIC PENETRATING SLAB W/FOAM WRAP. - SUPPORT AND SECURE WATER PIPING. - OK TO INSULATE HW. |