Permit: T06CM00967

Parcel: 13323164A


Addresses:

7150 E SPEEDWAY BL


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T06CM00967

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
05/26/2006 ELECTRIC - FINAL Approved IVRS - Inspection :*
05/25/2006 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
1. BOXES MORE THAN 1/4" FROM BOX TO SURFACE NEED APPROVED EXTENDER RINGS 314.20 METAL NOT APPROVED.
2. USE TERMINAL END FOR CONNECTION OF STRANDED WIRE TO SCREW TERMINATIONS.
3. PLEASE VERIFY MANUFACTURERS LISTING FOR ON EXHAUST FAN.
4. USE APPROVED LISTED FITTINGS FOR NON-METALLIC FLEX AND TIGHTEN.
5. PROTECT NON-METALLIC FLEX FROM SHARP EDGES.