Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM00963

Parcel: 141311270

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM00963

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
05/31/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
05/23/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999$
1) MISSING NAILING ON ROOF, MARKED IN BLACK
2) NEED B-5 TRUSS, SHOP DRAWING, NOT IN TRUSS BOOK
3) REAR P.A. MISSED SHEAR DIAPHRAM
4) SHIM ALL 3 PT BEARING TRUSS, NON 3 PT LEAVE GAP FOR DEFLECTION