Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM00961
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/12/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 05/31/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEE LAST INSPECTION |
|
| 05/25/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSED 4' OF NAILING AT JOINT NORTH SIDE 2) ADD SCAB AT JOINT SOUTH SIDE 3) INSTALL RAT RUNS 4) NAIL SHEAR PANELS TO ROOF 5) NAIL DRAG TRUSS 8D 6" ON CENTER 6) TWO BROKEN TRUSSES GABLE TO & NEXT ON EAST 7) NEED DEFINITION OF HEEL JOINTS (NO NOTCHING WITHIN 24" FROM JOINT) |