Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM00959
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/10/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 08/08/2006 | FRAMING | Partial Approval | 1) ITEM 03050 NOT REQUIRED/ALL ELECTRIC 2) NAIL TWO TOP PLATES TOGETHER 16D 12" ON CENTER D-1/17 3) INSTALL A35'S FLAT (BOTTOM CHORD TO SHEAR) GARAGE 4) EXTEND T & P |
|
| 08/03/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. ANTI-SIPHON REQ'D 2. FHA STRAPS @ OVERNOTCHED PLATES REQUIRE 8-16d NAILS EACH SIDE. 3. TIGHTEN REDHEADS 4. WIRE TOUCHING CAN LIGHT IN KITCHEN 5. SECURE RECEP. @ KITCHEN 6. SMOKIE MUST BE WITHIN 12" OF HIGHEST POINT IN MASTER BED. 7. BANG PLATES ON PLUMBING THROUGHOUT |
|
| 07/25/2006 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) COMPLETE ALL TRADES |