Permit: T06CM00954

Parcel: 141310640

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/13/2006 FRAMING Approved IVRS - Inspection :*
10/10/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CHECK TRUSS DRAWINGS FOR 3 PT BEARING AT GARAGE
2) REAR SHEAR PANELS NOT NAILED TO ROOF FROM LAST INSPECTION
3) NUMEROUS BOTTOM PLATES NOT SECURED, SEE TOP PLATE FRONT BEDROOM
4) CEILING JOIST HALL OVER SPAN
5) TWO DIVERTER STUDS OVER NOTCHED
6) NAIL 2 X 4 DBL AT GARAGE H.D. NAIL VERTICAL OR NAIL TO WALL SHEATHING
7) KITCHEN PEX TO CLOSE TO CAN, FHA STRAP AT PEX ON WALL
8) BANG PLATE HALL SHOWER H20