Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T06CM00920
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/29/2007 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
01/23/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO WATER HEATER AND FURNACE VENT WEATHER CAPS 2) POST TENSION CABLES MUST BE PROPERLY SEALED 3) STUCCO WEEP SCREED SEALD WITH GROUT 4) NUETRAL AND GROUND WIRES DAMAGED BY OVERTORQUING IN PANEL 5) ONE DEAD FRONT MOUNT SCREW STRIPPED WILL NOT TIGHTEN 6) PROVIDE PHYSICAL PROTECTION FOR UFER GROUND 7) SECURE A/C WHIP WITHIN 12" OF DISCONNECT 8) REMOVE GAS CONNECTOR FLEX AT DRYER |
|
01/22/2007 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER JIM |