Permit: T06CM00917

Parcel: 141095090

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T06CM00917

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
02/01/2007 ELECTRIC - FINAL Approved IVRS - Inspection :*
01/31/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
A reinspection fee has been assessed for this inspection. Multiple inspectio
01/29/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) W/H B-VENT MUST TERMINATE 8' FROM OR 2 FT ABOVE VERTICAL WALL
2) STUCCO WEEP SCREED COVERED WITH CONCRETE
3) PROVIDE 1/4" CLEARANCE TO SOIL AT WEEP SCREED
4) OVER TORQUED WIRES-DAMAGED IN SERVICE PANEL
5) SEAL HOLES IN GARAGE WALLS
6) GAS BOND CLAMP MUST BE EXPOSED
7) PROVIDE 1 1/2" CLEARANCE BETWEEN HAND RAIL AND WALL
8) CLAMP/SECURE GAS LINE IN ATTIC BY S.O.V.