Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/08/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 05/04/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SHEAR WALL NAILING OVERSPANNED THROUGHOUT. 2. PIECES OF SHEATHING IN SHEAR WALL NOT ADEQUATE. 3. SHEAR WALL IN GARAGE MISSING BOLTS AT BREAK ON BOTTOM PLATE. 4. SHEAR WALL IN GARAGE MISSING BLOCKING. 5. CABIN TIE OR STRAP ALL BREAKS IN DOUBLE. 6. NAIL LEDGER/BACK PORCH. 7. STRAP ALL GABLE ENDS. STOPPED INSPECTION. |