Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T06CM00890
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/24/2006 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
09/21/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PLUG OPEN KNOCKOUT IN PANEL 2) LABEL ALL BREAKERS 3) PROVIDE BUBBLE COVERS AT ALL WET LOCATION OUTLETS 4) COMPLETE DRYWALL REPAIR IN PANTRY 5) LIGHT IN PANTRY REQUIRES 12" CLEARANCE FROM VERTICAL PLANE OF SHELF 6) AA VALVE UNDER KITCHEN SINK REQUIRES 4" ABOVE FIXTURE DRAIN 7) STOPPED INSPECTION |