Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM00863
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/01/2006 | FRAMING | Approved | IVRS - Inspection :* | |
07/14/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ANTI-SIPHON ON HOSE BIBS 2) TIGHTEN ALL RED HEADS 3) ATTIC ACCESS IN GARAGE 4) FHA STRAP AT GAS LINE 5) SECURE WATER LINE AT BATH/GARAGE WALL 6) DRAFT STOP RING AT B-VENT 7) INSUFFICIENT NAILING AT FHA STRAPS 8) A/C CONDUCTORS MUST BE THROUGH EXTERIOR WALL 9) STOPPED INSPECTION-HOUSE NOT READY |
|
07/12/2006 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER SUPER |