Permit: T06CM00843

Parcel: 11016068B


Addresses:

6111 E GRANT RD


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T06CM00843

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
06/28/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
1) UNION ON T & P DRAIN LINE
06/26/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL HB VAC BREAKER
2) PROTECT PLASTIC VENT TERMINATION
3) AAV REQUIRES PLAN REVISION. DRAINAGE FITTING REQUIRED BELOW FLOOD RIM. A SAN "T" ON IT'S BACK IS NOT THE CORRECT USE OF THAT FITTING. IF CLEANOUT PLUG IS USED TO RECEIVE SCREW FROM COVER, THEN PLUG SHALL BE LISTED FOR SUCH USE
4) CORRECT LEAK ON T & P DRAIN
5) INSTALL EXPANSION TANK, DOWN STREAM OF SHUT OFF VALVE