Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/09/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 06/02/2006 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 05/25/2006 | FRAMING | Partial Approval | IVRS - Inspection :* STOCK ROOM TOYS R US HALLWAY C5/F5, BREAKROOM C2, DOORWAY E1/E2 OK TO SHEETROCK PROGRESS AREAS |
|
| 05/24/2006 | FRAMING | Partial Approval | IVRS - Inspection :* OFFICE (BABIES-R-US) OK TO SHEETROCK ONE SIDE. |
|
| 05/16/2006 | FRAMING | Partial Approval | IVRS - Inspection :* ENTRY AREA OK TO SHEETROCK; EXTERIOR OK |
|
| 05/02/2006 | FRAMING | Partial Approval | IVRS - Inspection :* MANGER'S OFFICE ONLY RECEIVED LETTER FROM ARCHITECT ALLOWING WOOD STUDS FOR FRAMING. |
|
| 04/24/2006 | FRAMING | Not ready for Inspection | IVRS - Inspection :* PLEASE PROVIDE A STAMPED LETTER FROM ARCHITECT STATING CHANGE TO WOOD FRAMING IN LIEU OF STEEL STUDS. |