Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T06CM00813

Parcel: 13314460A

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
04/11/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
2115, 2215, 2211, 2116, 2111, 2212, 2113, 2112

2214 - UNION LEAKING, DW HOSE
2216 - UNION LEAKING, CHINA BOWL CAP
2213 - UNION LEAKING
PAINT EXPOSED PLASTIC VENTS
04/05/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. ONLY ONE SLIP NUT ALLOWED ON STREAM OF P-TRAP
2. TEST TUBS
3. DISHWASHER HOSES
4. TRIM CLEANOUT SCREWS SO THEY DON'T PROTRUDE INTO DRAIN.
5. CORRECT LEAKS AT SERVICE VALVES.