Permit: T06CM00813

Parcel: 13314460A

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
01/05/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
PLEASE TEMPORARILY IDENTIFY UNITS FOR INSPECTION ON FUTURE UNITS.
01/03/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. 2115-2113 SECURE PIPING TO REF, CORRECT SLOPE ON WH DRAIN.
2. DO NOT BEND RIDGID COPPER AT SHWR RISERS
CORRECT 2111
3. PLUMB RISERS AT LAUNDRY BOXES ESPECIALLY IN 2112
4. DO A BETTER JOB SUPPORTING OVERHEAD COPPER
12/29/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) WATER TEST DWV
2) DOMESTIC WATER TO BE ON FOR INSPECTION
3) INSTALL GAGE ON BUILDING
4) CAP OPEN CLOSET BENDS AND ANY OPEN DRAIN PIPING
5) INSTALL HB VAC BREAKERS ON ALL HBS OR REMOVE HBS DURING CONSTRUCTION