Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/05/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* PLEASE TEMPORARILY IDENTIFY UNITS FOR INSPECTION ON FUTURE UNITS. |
|
| 01/03/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. 2115-2113 SECURE PIPING TO REF, CORRECT SLOPE ON WH DRAIN. 2. DO NOT BEND RIDGID COPPER AT SHWR RISERS CORRECT 2111 3. PLUMB RISERS AT LAUNDRY BOXES ESPECIALLY IN 2112 4. DO A BETTER JOB SUPPORTING OVERHEAD COPPER |
|
| 12/29/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) WATER TEST DWV 2) DOMESTIC WATER TO BE ON FOR INSPECTION 3) INSTALL GAGE ON BUILDING 4) CAP OPEN CLOSET BENDS AND ANY OPEN DRAIN PIPING 5) INSTALL HB VAC BREAKERS ON ALL HBS OR REMOVE HBS DURING CONSTRUCTION |