Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM00788
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/31/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
10/18/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) HOLDOWN EAST SIDE OF PATIO DOOR NOT ON SHEARWALL. 2) PROVIDE RETROFIT HOLDOWN 3) OK TO DRY IN |
|
10/16/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING CLIPS ON EXTERIOR WALLS-CARPENTER SUPER MARKED AREAS AS JOB WAS WALKED 2) MISSING DIAGONAL BRACE, BACK WALL 3) NEED DBL 2 X AT ALL SHEAR WALL CORNERS 4) MISSING STRAPS GLU LAM STAIR WAY 5) SHEARWALL STAIR WAY NEEDS LONGER STRAPS 6) GABLE PER 2/D2 |
|
10/12/2006 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED PER SUPER |