Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/08/2006 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* CORRECTIONS - OK FILL IN AROUND CLOSET BENDS AND SECURE FLANGE TO FLOOR AS REQUIRED BY UPC INSTALLATION STANDARDS. CALL FOR CLOSET FLANGE & SHOWER DRAIN INSPECTIONS UNDER PROGRESS OR FINAL. |
|
| 05/02/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK TO COVER ALL AREAS EXCEPT AT CORRECTIONS RETEST RECALL FOR INSPECTION WATER LEVEL IN TUB IS BELOW OVERFLOW LEVEL - FILL TO FLOOD RIM. SECURE CLOSET STUB OUT. PROVIDE 18" OF COPPER BETWEEN SWEAT VALVES & FLEXES AND PEX TUBING. TEST SHOWER RISERS. TRAP AND TRAP ARM SHALL BE THE SAME SIZE. CLOSET FLANGES SHALL BE SECURED TO FLOOR W/CORROSION RESISTANT FASTENERS. SHOWER DRAINS (NOT YET INSTALLED) SHALL BE FHA TYPE AND SHOWER PANS ARE TO BE TESTED. PIPING DIAGRAM DOES SHOW ABS. THIS IS OK WH'S INSTALLED ON A PLATFORM REQUIRE DRAIN PAN'S. |
|
| 04/28/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* |