Permit: T06CM00780

Parcel: 140180330


Addresses:

5023 S PARK AV #01

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
05/08/2006 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
03/28/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
PROVIDE PIPE WRAP PROTECTION THROUGH SLAB.
03/24/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
POST ADDRESS
1. 3" UPPER TERMINAL CLEAN-OUT REQUIRES A SWEEP AT THE VERTICAL TO HORIZONTAL CHANGE OF DIRECTION.
2. TWO WAY CLEAN-OUTS MUST BE FULL SIZED
ALL OTHER AREAS DWV WATER TEST OK
HAVE ARCHITECT SPECIFY THAT ABS IS OK FOR USE
IF ABS IS OK FOR USE, THEN YOU MAY COVER ALL AREAS
EXCEPT AT NECESSARY CORRECTIONS.