Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/25/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 07/17/2006 | FRAMING | Partial Approval | IVRS - Inspection :* 1) PENDING LATHE |
|
| 07/13/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLETE LATHE AROUND 2ND FLOOR FRONT WINDOW 2) SEAL LATHE AROUND SCUPPERS 3) CAP CHIMNEY 4) FIRESTOP GARAGE POP-OUT 5) REMOVE 3" WASTE STACK IN LR-STUD OVER BORED 6) CLEARANCE TO COMB. AROUND FIREPLACE FLUE 7) GROUND PANCAKE IN BEDROOM 8) FIRE STOP FURNACE FLUE |