Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM00755
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/28/2006 | FRAMING | Approved | IVRS - Inspection :* | |
12/13/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED 2 X POST UNDER 2 X 6 HEADER AT STAIR 2) CS 20 STRAP REQUIRED AT END OF STAIR SHEARWALL 3) PONY WALL AT STAIR MUST STAND 200 POUND LOAD 4) NAIL EXTERIOR WALL SILL PLATE TO FLOOR 16" ON CENTER 5) FIRESTOP W/H B-VENT 6) W/H B-VENT MUST HAVE MINIMUM 30 DEGREE PITCH |