Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T06CM00754
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/05/2007 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
01/31/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspection Property line sewer missing proper cleanout-4" does not fit 3" line Refee |
|
01/29/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO PROPERTY LINE SEWER CLEANOUT 2) PROVIDE 2" CLEARANCE BETWEEN WEEP SCREED AND CONCRETE, WEEP SCREED COVERED WITH CONCRETE 3) WIRES DAMAGED BY OVER TORQUE-REPAIR ALL WIRES AND TORQUE PER SPECS 4) NO GAS BOND ? MISSING EXPOSED CLAMP 5) PROVIDE 4" CLEARANCE BETWEEN WEEP SCREED AND SOIL 6) A/C CONDENSOR PAD MUST BE 3" ABOVE SOIL 7) SEAL WALL HOLE BY W/H S.O.V. 8) PROVIDE 30" VERTICAL ACCESS TO FURNACE AND SECURE GAS LINE SUPPORT |