Permit: T06CM00753

Parcel: 141095200

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM00753

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
10/11/2006 FRAMING Approved IVRS - Inspection :*
10/06/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSING KING STUD AT EACH END OF GARAGE DOOR OPENING
2) MISSING A34 ON GABLE END BRACING
3) DWV TEST NO WATER
4) A/C UNIT RETURN NEEDS TO BE 10' FROM SEWER VENT
08/16/2006 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) 1" CLEARANCE REQUIRED FROM W/H B-VENT TO COMBUSTIBLES
2) NO GAS BOND
3) SHEARWALLS NOT NAILED PER PLAN AT TOP PLATE
4) REMOVE NAILER HIDING SHEAR NAILING IN KITCHEN
5) SUPPORT DWV 90 AT ROOF PENETRATION-REVERSE PITCH M. BR.
6) UNABLE TO INSPECT KITCHEN LIVING ROOM AND FRONT BEDROOM M/BR EXTERIOR WALLS
7) REMOVE DRYWALL
8) STOPPED INSPECTION