Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM00753
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/11/2006 | FRAMING | Approved | IVRS - Inspection :* | |
10/06/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING KING STUD AT EACH END OF GARAGE DOOR OPENING 2) MISSING A34 ON GABLE END BRACING 3) DWV TEST NO WATER 4) A/C UNIT RETURN NEEDS TO BE 10' FROM SEWER VENT |
|
08/16/2006 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) 1" CLEARANCE REQUIRED FROM W/H B-VENT TO COMBUSTIBLES 2) NO GAS BOND 3) SHEARWALLS NOT NAILED PER PLAN AT TOP PLATE 4) REMOVE NAILER HIDING SHEAR NAILING IN KITCHEN 5) SUPPORT DWV 90 AT ROOF PENETRATION-REVERSE PITCH M. BR. 6) UNABLE TO INSPECT KITCHEN LIVING ROOM AND FRONT BEDROOM M/BR EXTERIOR WALLS 7) REMOVE DRYWALL 8) STOPPED INSPECTION |