Inspection History: FRAMING

Permit Number - T06CM00746

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
08/15/2006 FRAMING Approved IVRS - Inspection :*
08/11/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REMOVE DRYWALL FROM WALLS FOR ANCHOR BOLT INSPECTION. REMOVE INSULATION FROM ALL ANCHOR BOLTS
08/10/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 1 ANCHOR BOLT LOOSE AND MISSING
08/08/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ITEMS 3, 7 AND 8 FROM PRIOR INSPECTIONS NOT DONE
2) DWV TEST ? FILLED UP-WILL REINSPECT AT NEXT INSPECTION
3) REMOVE INSULATION FROM ANCHOR BOLTS
08/02/2006 FRAMING Not ready for Inspection IVRS - Inspection :*
07/26/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO POTABLE WATER TEST
2) NO GAS TEST
3) RED HEAD ANCHOR BOLTS LOOSE
4) NO DWV WATER TEST
5) ANCHOR BOLTS MISSING THROUGHOUT
6) ELECTRIC AND MECHANICAL NOT COMPLETE MASTER BATH
7) FIRE STOP WALLS
8) BLOCK DUCT BOOTS
9) GAS LINE MUST TERMINATE WITHIN 36" OF FAU CONNECTION