Permit: T06CM00745

Parcel: 141095060

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM00745

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
08/10/2006 FRAMING Approved IVRS - Inspection :*
08/08/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) DRYER DUCT CANNOT EXHAUST IN ATTIC
2) STAIR LIGHT MUST BE 6'-8" ABOVE FLOOR
3) EXPOSE ANCHOR BOLTS FOR INSPECTION
4) ITEMS 2, 8, 9 AND 12 FROM PRIOR INSPECTION NOT DONE
07/26/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) STUCCO POP OUT NOT DONE
2) 1" CLEARANCE REQUIRED BETWEEN WATER HEATER B-VENT AND WOOD
3) BEARING WALLS REQUIRE TWO ANCHOR BOLTS PER PLATE
4) STAIR RISERS EXCEED 3/8" DIFFERENCE
5) NAIL GARAGE SHEARWALLS THRU FLOOR PER 12/D6
6) SECOND FLOOR SILL PLATES AT SHEAR WALLS NOT NAILED PER PLAN
7) NO DWV WATER TEST
8) 1, 2, 3, 4, AND 5/D3 NOT COMPLIED WITH AT SECOND FLOOR SHEARWALL
9) FLOOR JOIST HANGERS NOT NAILED
10) FIRE BLOCK THROUGHOUT
11) NO POTABLE WATER TEST
12) FIRE BLOCK COMBUSTION AIR