Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM00745
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/10/2006 | FRAMING | Approved | IVRS - Inspection :* | |
08/08/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DRYER DUCT CANNOT EXHAUST IN ATTIC 2) STAIR LIGHT MUST BE 6'-8" ABOVE FLOOR 3) EXPOSE ANCHOR BOLTS FOR INSPECTION 4) ITEMS 2, 8, 9 AND 12 FROM PRIOR INSPECTION NOT DONE |
|
07/26/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) STUCCO POP OUT NOT DONE 2) 1" CLEARANCE REQUIRED BETWEEN WATER HEATER B-VENT AND WOOD 3) BEARING WALLS REQUIRE TWO ANCHOR BOLTS PER PLATE 4) STAIR RISERS EXCEED 3/8" DIFFERENCE 5) NAIL GARAGE SHEARWALLS THRU FLOOR PER 12/D6 6) SECOND FLOOR SILL PLATES AT SHEAR WALLS NOT NAILED PER PLAN 7) NO DWV WATER TEST 8) 1, 2, 3, 4, AND 5/D3 NOT COMPLIED WITH AT SECOND FLOOR SHEARWALL 9) FLOOR JOIST HANGERS NOT NAILED 10) FIRE BLOCK THROUGHOUT 11) NO POTABLE WATER TEST 12) FIRE BLOCK COMBUSTION AIR |