Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM00722

Parcel: 140264260

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM00722

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
04/25/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
04/20/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) HOLDOWNS SHALL BE NAILED TO 2 KING STUDS
2) COMPLY WITH DETAIL D2-2
3) NAIL EXT. SHEAR TO DBL STUDS AT HOLDOWNS FRONT SOUTH WINDOW