Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T06CM00720

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
08/08/2006 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
02/28/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*OK TO COVER ?? PROVIDE FOAM PIPE WRAP ON PIPING PASSING THROUGH CONCRETE
02/27/2006 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) STILL HAVE 7 LOCATIONS ON DRAIN LINES WITH LESS THAN 2 PERCENT SLOPE-2 PERCENT IS MINIMUM
02/24/2006 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
ROUGH PIPING IS IN VIOLATION OF UPC SEC 708
'HORIZONTAL DRAINAGE PIPING SHALL BE RUN IN PRACTICAL ALIGNMENT AND A UNIFORM SLOPE."
PROVIDE 1/4" PER FOOT SLOPE THROUGHOUT