Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/24/2006 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* WATER TEST GREASE INTERCEPTOR INSTALL WITH VENT BACK UP IN BUILDING, CONNECTION TO 4" SANITARY 10' DOWNSTREAM OF IN LINE CLEANOUT APPROVED. |
|
| 05/12/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* - WATER TEST WASTE & VENT SANITARY TO 2-WAY CLEANOUT UNDERSLAB ONLY OK. - PENDING REVISION FOR CORRECT VENTING OF ISLAND FIXTURES. - WATER TEST GREASE WASTE TO 2-WAY CLEANOUT OK - PENDING REVISION FOR RECONFIGURATION OF 3-COMP, 2-COMP & HAND SINKS ON THIS SYSTEM PER 8 1/2 X 11 ON SITE SERVING AS REDLINE MY INITIAL. 3" GREASE INTERCEPTOR STUB IN & OUT OF BUILDING OK |