Permit: T06CM00666

Parcel: 140295830

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM00666

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
06/30/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
06/19/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) STRAP GABLE ENDS
2) SHEAR PANELS NOT REACHING TOP PLATE
3) OVER SPAN ON STUD WEST WALL AND NORTH WALL
4) MISSING KING STUD 2ND FLOOR GIRDER NORTH EAST CORNER
5) STRAP BREAKS ON DBL TOP PLATE NORTH WALL 2 X 6 TO 2 X 4 WALL