Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM00665

Parcel: 140294790


Addresses:

3873 E SUN VIEW CT


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM00665

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
06/30/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
06/29/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) EAST SIEE OF HOUSE MISSING CLIPS THROUGHOUT
2) KING STUDS OVER NOTCHED EAST SIDE 2ND FLOOR
3) FHA STRAP BREAK DBL TOP PLATE
4) GABLE END NOT CLIPPED THROUGHOUT
5) NORTH SIDE STRAP DBL TOP PLATE AT BREAK
6) MISSING CLIPS AT WINDOW KING STUD 2ND FLOOR
7) CLIPS ON 2ND FLOOR WINDOW KING STUD
8) H2.5 ON FRONT PORCH
9) STOPPED INSPECTION