Inspection Status: Denied
Inspection History: FRAMING
Permit Number - T06CM00656
Inspection Description - FRAMING
Inspection Status - Denied
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/25/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LSL BEAM AT KITCHEN CEILING NOT RESTING ON DBL 2 X POST & NOT SECURED AT GARAGE 2) SECURE ABS PLUMBING TRAPS & WATER CLOSET UNDER FLOOR-DO NOT USE PLUMBERS TAPE 3) P-2 & P-3 SHEAR CALL FOR 1/2" BOLTS AT 18" ON CENTER COMPLY |
|
05/25/2006 | FRAMING | Approved | IVRS - Inspection :* | |
05/22/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED TPR DRAIN LINE 2) NEED GAS TEST 3) FIRE BLOCK KITCHEN PENINSULA CHASE 4) INSTALL 2 X HEADERS ON 2 SETS OF LOWER STRINGERS 5) STRAP H20 HEATER FLUE 6) INSTALL X BRACING 7) 1" CLEARANCE TO FURNACE FLU 8) INSTALL MASTER VENT FAN 9) GABLE ENDS NOT DONE 10) H20 AND DWV OK |