Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/13/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 04/10/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PRIOR REQUEST NOT COMPLIED WITH |
|
| 04/05/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHIM STUDS AND NAILS-NUMEROUS UNDER SIZE, NOT TOUCHING BOTTOM PLATE 2) #5 SHEAR SHALL BE NAILED AT 3" ON CENTER |
|
| 03/31/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) MISSED P.A.'S AT REAR 2) USE MINIMUM (16D SINKERS .148) IN P.A.'S SEE SIMPSON BOOK 3) JOINTS ON TOP PLATES TO BREAK OVER STUDS |