Permit: T06CM00607

Parcel: 11624101A

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/11/2006 FRAMING Approved IVRS - Inspection :*
04/03/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BEARING AT EXTERIOR TRUSSES NOT FRAMED PER DETAIL 5/A-1
2) INSTALL BOTTOM PLATE ANCHOR BOLTS WITHIN 12" EACH END BOTTOM PLATES
3) FILL IN GAPS BEARING STUDS ABOVE HEADERS AND HEADER AT BEARING PENCILLED IN ADDITIONS TO ELECTRIC TO BE SUBMITTED AND APPROVED BY CITY PLAN CHECK
4) PLAN SHOWS 125 AMP MAIN PANEL (200 AMP EXISTS)
5) NEW SUB PANEL INSTALLED ALSO-NOT ON PLAN ?
02/15/2006 FRAMING Not ready for Inspection 1) TO BE INSPECTED WITH ELECTRIC