Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/20/2006 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 04/18/2006 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 04/17/2006 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO ONE PRESENT FOR ACCESS 2) DOORS LOCKED |
|
| 04/10/2006 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MAKE UP ELECTRIC AT EACH BOX 2) PROVIDE TEMP GFI AND 20 AMP BREAKER AT SERVICE PANEL 3) PROVIDE WATER TEST ON TOP OUT ABS AND PEX 4) DUCT WORK NOT COMPLETE AT HALLWAY 5) SECURE ELECTRIC MAX 12" FROM BOX 6) PROVIDE BOX FOR EXTERIOR LIGHTS 7) PROVIDE NAIL PROTECTION THROUGHOUT HOUSE 8) LOWER SMOKE DETECTOR AT HALLWAY 6" FROM TOP WALL 9) MOVE SMOKIES 3' FROM VENTS 10) PROVIDE GFI AT WEST SIDE OF SINK |