Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T06CM00596
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/29/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
06/24/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* PROTECT VENT TERMINATION FROM UV RAYS. SEAL WALL PENETRATION. CORRECT LEAKING BACKFLOW PREVENTOR. INSTALL CLEANOUT PLUGS DESIGNED TO RECEIVE SCREW OF C/O COVER, PLUGS SHALL HAVE A FACTORY TAPE. DRILLING AND TAPPING OF PLASTIC IS PROHIBITED BY CODE. HAVE COVERS REMOVED FOR INSPECTION. |