Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/10/2006 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 07/25/2006 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED NAIL PROTECTION PLATES ON ALL STUDS AND PLATES WHERE WIRING IS WITHIN 1 1/4" OF FACE AND FOR PLUMBING 2) NEED ANOTHER OUTLET TO LEFT OF NORTH WINDOW 3) BOND WIRE, BETWEEN GAS AND WATER LINES, MUST CONTINUE ON TO GROUND 4) HOT WATER HEATER FLUE MUST HAVE 1" CLEARANCE TO COMBUSTIBLES 5) NEED VENT FAN DUCTS INSTALLED 6) BLOCK DUCT BOOTS ON 3 SIDES 7) WASHER VERTICAL DRAIN PIPE IS TO LONG-TRAP SHOULD BE 6" TO 18" ABOVE THE FLOOR AND STAND PIPE IS 30" MAX 8) PLASTIC SUPPLY PIPING MUST BE 12" FROM ANY CAN LIGHT 9) NEED DWV TEST |