Permit: T06CM00585

Parcel: 103182050

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
04/14/2006 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
04/11/2006 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED VERIFICATION OF NEW ANCHOR BOLTS MINIMUM 7" EBEDMENT INTO EXISTING FOUNDATION
2) MINIMUM 12" X 12" FOOTINGS FOR PORCH POSTS
3) REBAR TO BE MINIMUM 3" FROM DIRT
4) BROKEN BLOCK SUPPORTING REBAR TO LARGE
5) STOPPED INSPECTION
6) PLAN CALLS FOR 4 FOOTINGS (5 EXISTS) HAVE PLAN REVISED