12/14/2006 BUILDING - FINAL Approved IVRS - Inspection :*
12/11/2006 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) DBL LUGGING OF WIRES OF DIFFERENT GAUGE ON SAME LUG NOT ALLOWED-READ EQUIPMENT LABEL
2) INSTALL 1/4" SCREEN ON RANGE VENT
3) WEATHER PROOF OUTLET COVER INSTALLED UP SIDE DOWN BY A/C
4) MARK PAU LABEL FOR PROPER HEAT STRIP KITCHEN SEE LABEL
5) M/CLOSET FLUORESCENT LIGHT MUST BE 6" HORIZONTALLY FROM CLOSET SHELF
6) CONVENIENCE OUTLET IS NOT ALLOWED UNDER COUNTER OVERHANG GREATER THAN 6" AT KITCHEN BAR TOP