Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T06CM00571
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/14/2006 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 12/11/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DBL LUGGING OF WIRES OF DIFFERENT GAUGE ON SAME LUG NOT ALLOWED-READ EQUIPMENT LABEL 2) INSTALL 1/4" SCREEN ON RANGE VENT 3) WEATHER PROOF OUTLET COVER INSTALLED UP SIDE DOWN BY A/C 4) MARK PAU LABEL FOR PROPER HEAT STRIP KITCHEN SEE LABEL 5) M/CLOSET FLUORESCENT LIGHT MUST BE 6" HORIZONTALLY FROM CLOSET SHELF 6) CONVENIENCE OUTLET IS NOT ALLOWED UNDER COUNTER OVERHANG GREATER THAN 6" AT KITCHEN BAR TOP |