| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/18/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 07/05/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) AT GARAGE HEADER, NO BEARING UNDER TRIM STUDS 2) TRUSS #R1D (WEB CONFIGURATION), NOT PER DRAWING 3) REAR SHEAR WALL TRANSFER 17/D1 DOESN'T ALLOW LADDER BLKS FOR TRANSFER, WALL DOESN'T GO UP TO BOTTOM CORD 4) NAIL DRAG STRUTS TO ROOF 8D AT 8" ON CENTER |