Permit: T06CM00553

Parcel: 136154930


Addresses:

7962 E SENATE ST


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM00553

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
04/25/2006 FRAMING Approved IVRS - Inspection :*
04/21/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED POSITIVE ATTACHEMENT OF F2XLC1 WEST END
2) INSTALL DROP CEILING POWDER ROOM
3) COMPLETE FRONT
4) SECURE 10-3 WIRE NEAR STAIRS
5) SUPPORT ABS EVERY 4'
6) MAXIMUM 30 DEGREE PITCH ON WATER HEATER B-VENT
7) NAIL STOPS CONDENSATE
8) STAT WIRE ON B-VENT
9) EXTEND DRYER VENT THRU ROOF