Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/27/2007 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 08/24/2007 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 08/22/2007 | ELECTRIC - INTERMEDIATE | Cancelled | ||
| 08/22/2007 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 08/17/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GROUND METAL BOXES 2) SECURE ALL ROMEX 8" FROM BOXES THROUGHOUT 3) INSTALL PROTECT WIRING 1 1/4" FROM EDGE 5) SUMMIT AS BUILT FOR REMOVALS |
|
| 07/24/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) STAPLE WIRES WITH APPROVED CABLE STAPLES WITHIN 8" OF BOXES 2) USE ROMEX CONNECTORS IN METAL BOXES AND GROUND METAL BOXES 3) THHN WIREN CANNOT BE RUN IN WALLS OUTSIDE OF CONDUIT 4) SECURE 4 GANG BOX BOTH ENDS |