Permit: T06CM00544

Parcel: 13331156A

Inspection Status: Approved

Inspection History: SHEET ROCK NAILING

Date Description Inspector Results Comments
05/10/2006 SHEET ROCK NAILING Approved IVRS - Inspection :*
05/04/2006 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*
OK TO TAPE WALLS & CEILINGS THAT ARE "NOT" FIRE BARRIERS, FIRE BARRIERS MUST BE CAULKED IN ACCORDANCE WITH ** SEE NOTES BELOW #'S 104, 203, 204
05/02/2006 SHEET ROCK NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE LISTED FIRESTOP SYSTEM FOR AREA SEPARATION WALLS AND INSTALL SYSTEM.
2. 2 LAYERS 5/8 TYPE X REQUIRED ON CEILING OF #104
05/01/2006 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*
EXCLUDING NORTH PARTY WALL (NEEDS TO BE 5/8" THICK)
1. PLEASE CAULK ANY JOINTS LARGER THAN 1/16" & ANY PENETRATIONS WITH A U.L LISTED, INTUMESCENT FIRE CAULK.