Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T06CM00539
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/03/2008 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 03/27/2008 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE CORRECT DRAINAGE FOR HAND SINK NOTE: 1 1/2 DRAIN ARM CANNOT EXCEED 42", 2" CAN GO 5' WITH ONLY 90 DEG. CHANGE OF DIRECTION, 2" ARM REQUIRES 2" P-TRAP 2. PROVIDE BACKFLOW PROTECTION FOR SPRAYER AT UTENSIL WASHER |
|
| 08/09/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* MONEY ORDER #08-532660704 FLOOR SINK IN BAKERY/DELI PAN WASHER OK |
|
| 07/20/2006 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | 1) ROUGH SOIL 4" GREASE WASTE FROM CONNECTION TO SANITARY SEWER THRU GREASE INTERCEPTOR. UP STREAM 2" TO CORNER WHERE GREASE WASTE ENTERS BLDG OK |