Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T06CM00539
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/07/2008 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 03/25/2008 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* RECALL WHEN READY |
|
| 09/25/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. MC CABLE RUN ON TOP OF CEILING GRID IN PRODUCE TO DELI NEEDS TO BE SUPPORTED PROPERLY 2. STRAP MC CABLE WITHIN 12" OF JUNCTION BOXES ON FEEDS TO TRACK LIGHTS 3. INSTALL EXTENSIONS ON RECEPTACLES INSTALLED IN WOOD PANELS 4. ENSURE RECEPTACLES SECURED TIGHTLY TO WALL SURFACE 5. RECALL WHEN COMPLETE & FOR REST AT FINAL |
|
| 07/17/2007 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. NEED REVISED & APPROVED SET OF DRAWINGS FOR WORK THAT WAS DONE 2. WHEN CALLING FOR FINALS NEED TO INSPECT STORE IN SECTIONS. ALSO, NO CEILING INSPECTIONS WERE DONE NEED TO HAVE LADDER OR LIFT TO INSPECT CEILINGS. 3. RECALL WHEN READY |
|
| 03/29/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* NEED REVISED SET OF DRAWINGS THAT SHOWS EXACTLY WHAT WORK HAS BEEN DONE & WHAT WAS ELIMINATED. |
|
| 01/30/2007 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* CANCELLED BY OFFICE |