Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM00532

Parcel: 131050030


Addresses:

5472 E 29TH ST


Inspection Status: Approved

Inspection History: PLUMBING - PROGRESS

Permit Number - T06CM00532

Inspection Description - PLUMBING - PROGRESS

Inspection Status - Approved

Date Description Inspector Results Comments
08/01/2006 PLUMBING - PROGRESS Approved IVRS - Inspection :*
07/06/2006 PLUMBING - PROGRESS Denied IVRS - Inspection :
See detailed listing on site.| 999*
A REINSPECTION FEE WILL BE APPLIED IF YOU ARE NOT READY NEXT TIME.
07/03/2006 PLUMBING - PROGRESS Denied IVRS - Inspection :
See detailed listing on site.| 999*
06/30/2006 PLUMBING - PROGRESS Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE PLUMBING INSTALL FOR PLAN. 1 1/2 LAV DRAIN ARM SHALL NOT BE OVER MAX. LENGTH OF 42"
2. DRAINAGE FITTING TO BE APPROVED FITTING FOR DRAINAGE.
3. WASTE & VENT TO BE TESTED THRU ROOF.
4. PROVIDE APPROVED COUPLING FROM CAST IRON TO ABS PLASTIC.
5. SECURE ALL WATER PIPING.
6. REMOVE AND CAP ALL UNNEEDED PIPING CORRECTLY.
7. INSTALL OF WATER HEATER TO BE PER PLAN FOR FINAL.
8. ALL CLEANOUTS FOR TEST TO BE ACCESSIBLE.