Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM00531
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/27/2006 | FRAMING | Approved | IVRS - Inspection :* | |
07/25/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REPLACE WIPED FITTINGS AND MIS-ALIGNED FITTINGS AT M. TUB REPEAT 2) SECOND FLOOR SHEARWALL NOT NAILED AT 8" ON CENTER |
|
07/13/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) STRAP AND NAIL SECOND FLOOR SHEARWALL 2) FIREBLOCK BR OVER ENTRY 3) SECURE ELECTRIC BOX MIDDLE B/R 4) KITCHEN HOLDOWN MISSING NUT 5) DWV LEAK MASTER BATH-MIS ALIGNED FITTINGS |