Permit: T06CM00521

Parcel: 13329012E

Inspection Status: Approved

Inspection History: SHEET ROCK NAILING

Date Description Inspector Results Comments
02/22/2006 SHEET ROCK NAILING Approved IVRS - Inspection :*
02/17/2006 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*
OK TO TAPE LOWER HALF OF WALLS
02/16/2006 SHEET ROCK NAILING Not ready for Inspection IVRS - Inspection :*
1. AT WALLS ADJACENT TO OR WITH ADJOINING UNITS, THE SHEETROCK MUST EXTEND TO BOTTOM OF DECK.
2. ANY PENETRATIONS @ THE ABOVE MENTIONED WALLS & ANY JOINTS THAT ARE MORE THAN 1/16" MUST BE FIRE CAULKED WITH A U.L. LISTED INTUMESCENT CAULK (INCLUDING CEILING/HARD LIDS & ABOVE CEILING PENETRATIONS @ WALLS) TO ADJOINING UNITS.
- PLEASE LEAVE A TUBE OF CAULK FOR VERIFICATION
- CAULK SHOULD BE THE DEPTH OF SHEETROCK