Inspection Status: Approved
Inspection History: SHEET ROCK NAILING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/22/2006 | SHEET ROCK NAILING | Approved | IVRS - Inspection :* | |
| 02/17/2006 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* OK TO TAPE LOWER HALF OF WALLS |
|
| 02/16/2006 | SHEET ROCK NAILING | Not ready for Inspection | IVRS - Inspection :* 1. AT WALLS ADJACENT TO OR WITH ADJOINING UNITS, THE SHEETROCK MUST EXTEND TO BOTTOM OF DECK. 2. ANY PENETRATIONS @ THE ABOVE MENTIONED WALLS & ANY JOINTS THAT ARE MORE THAN 1/16" MUST BE FIRE CAULKED WITH A U.L. LISTED INTUMESCENT CAULK (INCLUDING CEILING/HARD LIDS & ABOVE CEILING PENETRATIONS @ WALLS) TO ADJOINING UNITS. - PLEASE LEAVE A TUBE OF CAULK FOR VERIFICATION - CAULK SHOULD BE THE DEPTH OF SHEETROCK |