Permit: T06CM00438

Parcel: 11615194B

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Permit Number - T06CM00438

Inspection Description - ELECTRIC - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
06/15/2006 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
06/13/2006 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1. LAUNDRY SWITCH BOX IS OVERFILLED.
2. NEED NAIL PLATES IN KITCHEN
3. SOME BOXES ARE NOT NAILED ON ALL THE WAY OR CROOKED.
4. HAVE CONDUCTORS COMPRESSED AGAINST GAS PIPE AT DISPOSAL.
5. CHECK THAT EQUIPMENT GROUND SCREWS ARE TIGHT IN METAL BOXES.
6. CABLES WITHIN 6' OF ATTIC ACCESS MUST BE PROTECTED.